$42.30
The MeanWell HSP-300-5 is a robust 300W switching power supply engineered to deliver stable, high-performance power for professional LED display systems, with a reliable 5V DC output at 60A. Built on MeanWell’s industry-leading quality standards, this unit features active PFC, a wide 90–264V AC input range, and comprehensive protections against overload, overvoltage, and short circuits—making it the ideal choice for large-format indoor full-color LED screens, digital billboards, and commercial display installations. With a compact, fan-cooled design and compliance with global safety certifications (CE, UL, RoHS), it ensures consistent, uninterrupted performance for integrators and end-users in demanding environments.
As a trusted power solution for LED projects worldwide, the MeanWell HSP-300-5 offers seamless compatibility with a broad range of LED modules and control systems, streamlining integration and reducing project downtime. Backed by MeanWell’s global service network and a 3-year warranty, this power supply provides the durability and technical support required for mission-critical applications. Whether you’re designing a new LED display installation or upgrading an existing system, the HSP-300-5 delivers the reliability, efficiency, and peace of mind that define professional-grade power solutions for the LED industry.
Case:806 Size:215×115×30mm
Power: 300W
High efficiency up to 90%
Built-in active PFC function, PF>0.95
LED indicator for power on
Forced air cooling by built in DC Fan with fan speed control function
1U low profile 30mm
High efficiency, Long life and high reliability
Protections: Short circuit / Overload / Over voltage / over temperature
1 year warranty
Product Specifications :
| Model | HSP-300-5 | |
| Input | Voltage Range | 85~ 264VAC 120~ 370VAC |
| FREQUENCY RANGE | 47 ~ 63Hz | |
| AC CURRENT (Typ.) | 3.5A/115VAC 1.5A/230VAC | |
| LEAKAGE CURRENT | <2mA / 240VAC | |
| INRUSH CURRENT (Typ.) | COLD START 65A/230VAC | |
| EFFICIENCY (Typ.) | 87% | |
| Output | RATED CURRENT | 60A |
| DC VOLTAGE | 5V | |
| RATED POWER | 300W | |
| CURRENT RANGE | 0-60A | |
| VOLTAGED ADJ. RANGE | 4.75~ 5.5V | |
| RIPPLE & NOISE (max.) Note.2 | 100mVp-p | |
| VOLTAGE TOLERANCE Note.3 | ±2.0% | |
| LOAD REGULATION Note.5 | ±1.5% | |
| LINE REGULATION Note.4 | ±0.5% | |
| HOLD UP TIME | 20ms at full load | |
| SETUP, RISE TIME | 600ms,40ms at full load | |
| Protection | OVER VOLTAGE | 5.5~ 6.75V Protection type :Shut off 0/p volltage, clamping by zener diode |
| OVER LOAD | Above 150% rated output power Protection type :Hiccup mode, recovers automatically after fault condition is removed |
|
| Safety | WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
| SAFETY STANDARDS Note 6 | UL60950-1, CB(IEC60950-1),CCC GB4943, 1:2011 approved | |
| ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH | |
| EMC STANDARDS | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, GB9254 | |
| Environment | WORKING HUMIDITY | 20 ~ 90% RH non-condensing |
| WORKING TEMP | -20 ~ +70 (Refer to output load derating curve) | |
| TEMP. COEFFICIENT | ± 0.03%/℃ (0 ~ 50℃) | |
| STORAGE TEMP., HUMIDITY | -40 ~ +85 , 10 ~ 95% RH | |
| VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | |
| Others | DIMENSION | 215*115*30mm (L*W*H) |
| MTBF | 1608.8K hrs min. MIL-HDBK-217F (25 ) ℃ | |
| Note | I. Al parameters NOT specialy mentioned are measured at 230VAC input. rated load and 25℃ of ambient temperature. 2 Ripple & noise are measured at 20MHz Of bandwidth by usig a I2′ twisted pair-wire terminated with a 0.1UI & 470 Parallel capacitor 3. Tolerance : includes set up tolerance. line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. For the request of GEl4943.1.the power soppy is only suable for use in the altitude 2000m below and the non tropical climate condrtion. 7. The power supply is considered a component which will be instated into a final equipment The final equipment must be re-confirmed that it still mesh EMC drectives. For guidance on how to perform the EMC tests. please refer to ‘EMI testing of component power supplies’ |
|